Direct Buried Optical Cables

Direct Buried Optical Cables     Gel-Free Loose Tube Armored Cable


GYFTY53-Direct buried in frequently lighting areas
Fiber reinforced plastic central strength member, Loose tube stranded, PE inner sheath, Corrugated steel tape armored double PE sheath.

 


 

Performance 

Application
Under ground, long haul and building network communication
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~36

14.1

193

6

6

2700

1000

3000

1000

38~72

15.1

212

12

6

2700

1000

3000

1000

74~96

16.3

246

12

8

2700

1000

3000

1000

98~120

17.8

288

12

10

2700

1000

3000

1000

122~144

19.4

336

12

12

2700

1000

3000

1000

>144

Available upon customer's request

*Customized cable structure is available

 

 

 

Direct Buried Optical Cables     Steel Wires Armored Cable


GYTY33-Direct buried/underwater/Aerial
Phosphate or galvanized steel wire central strength member, Loose tube stranded aluminum tape armor, PE inner sheath, Steel wire armored, PE outer sheath outdoor cable.

 


 

Performance 

Application
Long haul and building network communication
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~30

15.5

407

6

5

10000

4000

5000

3000

32~36

16

437

6

6

10000

4000

5000

3000

38~60

16.6

463

12

5

10000

4000

5000

3000

62~72

17.2

499

12

6

10000

4000

5000

3000

>72

Available upon customer's request

*Customized cable structure is available

 

 

 

Direct Buried Optical Cables     All Terrin Cable


GYTA33-Direct buried/underwater/Aerial
Phosphate or galvanized steel wire central strength member, Loose tube stranded aluminum tape armor, PE inner sheath, Steel wire armored, PE outer sheath outdoor cable.

 


 

Performance 

Application
Under ground, long haul and building network communication
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~30

17.3

540

6

5

10000

4000

5000

3000

32~36

17.8

578

6

6

10000

4000

5000

3000

38~60

18.3

603

12

5

10000

4000

5000

3000

62~72

18.8

647

12

6

10000

4000

5000

3000

>72

Available upon customer's request

*Customized cable structure is available