Duct Optical Cables

Duct Optical Cables     Gel-Free Loose Tube All Dielectric Cable


GYFY-Duct/Aerial
Fiber reinforced plastic central strength member, Tube filling gel, Loose tube stranded, PE sheath outdoor cable.

 


 

 

Performance 

Application
Long haul and building network communication 
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~36

10.2

85

6

6

1500

600

1000

300

38~72

11.1

100

12

6

1500

600

1000

300

74~96

12.6

130

12

8

1500

600

1000

300

98~120

14.1

162

12

10

1500

600

1000

300

122~144

15.9

204

12

12

1800

600

1000

300

146~216

15.9

205

12

18(2layers)

1800

600

1000

300

>216

Available upon customer's request

*Customized cable structure is available

 

 

 

Duct Optical Cables     Gel-Filled Loose Tube All Dielectric Cable


GYFTY-Duct/Aerial
Fiber reinforced plastic central strength member, Tube filling gel, Loose tube stranded, PE sheath outdoor cable.

 


 

Performance 

Application
Long haul and building network communication 
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~36

10.2

85

6

6

1500

600

1000

300

38~72

11.1

100

12

6

1500

600

1000

300

74~96

12.6

130

12

8

1500

600

1000

300

98~120

14.1

162

12

10

1500

600

1000

300

122~144

15.9

204

12

12

1800

600

1000

300

146~216

15.9

205

12

18(2layers)

1800

600

1000

300

>216

Available upon customer's request

*Customized cable structure is available

 

 

 

Duct Optical Cables    Gel-Filled Loose Tube Armored Cable (Single Sheath)


GYFTS/A-Duct/Aerial
Fiber reinforced plastic central strength member, Loose tube stranded, Corrugated steel tape armored outdoor cable.

 

 


 

Performance 

Application
Long haul and building network communication 
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~36

11.4

130

6

6

1500

600

1000

300

38~72

12.5

152

12

6

1500

600

1000

300

74~96

14.2

194

12

8

1500

600

1000

300

98~120

15.7

230

12

10

1500

600

1000

300

122~144

17.3

274

12

12

1800

600

1000

300

>144

Available upon customer's request

*Customized cable structure is available

 

 

 

Duct Optical Cables    Gel-Filled Loose Tube All Dielectric Cable (Double Sheath)


GYFTCY-Duct/Aerial/Direct Buried
Fiber reinforced plastic central strength member, Loose tube stranded, PE sheath all-dielectric, Self-supporting aerial cable.

 


 

Performance 

Application
The actual status of overhead power lines
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~36

10.7

92

6

6

2700

1000

1000

300

38~72

11.6

103

12

6

2700

1000

1000

300

74~96

13.3

149

12

8

2700

1000

1000

300

98~120

14.8

180

12

10

2700

1000

1000

300

122~144

16.4

222

12

12

2700

1000

1000

300

146~216

18.8

224

12

18(2layers)

2700

1000

1000

300

>216

Available upon customer's request

*Customized cable structure is available

 

 

 

Duct Optical Cables    Corrugated Steel/Aluminum Tape Armored Cable (Single Sheath)


GYFS/A-Duct/Aerial
Fiber reinforced plastic central strength member, Loose tube stranded, Corrugated steel tape armored outdoor cable.

 


 

Performance 

Application
The actual status of overhead power lines
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Fibers

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

2~36

9.9

110

6

5

1500

600

1000

300

38~72

10.6

133

6

6

1500

600

1000

300

74~96

11.4

140

12

5

1500

600

1000

300

98~120

12

168

12

6

1500

600

1000

300

122~144

13.6

202

12

8

1800

600

1000

300

>144

Available upon customer's request

*Customized cable structure is available

 

 

 

Duct Optical Cables    Gel-Filled, Corrugated Steel/Aluminum Tape Armored Ribbon Cable


GYDTA/S-Duct/Aerial
Phosphate or galvanized steel wire central strength member, Loose tube stranded, Corrugated steel tape armored double PE sheath.

 


 

Performance 

Application
The actual status of overhead power lines
Operating Temperature
-40
℃~+70℃

Technical Specification

Fiber Count

Nominal

Nominal

Max Ribbon

No. of

Allowable Tensile Load(N)

Allowable Crush Resistance

Diameter(mm)

Weight(kg/km)

per Tube

(Tubes +Fillers)

(N/100mm)

 

 

 

 

Short Term

Long Term

Short Term

Long Term

4-Fiber Ribbon

8~96

15.4

217

4

6

1500

600

1000

6-Fiber Ribbon

12~120

15.6

220

4

5

1500

600

1000

126~144

16.3

226

6

4

1500

600

1000

150~216

18.8

307

6

6

2200

600

1000

8-Fiber Ribbon

8~192

16.8

240

6

4

1500

600

1000

200~288

19.7

320

6

6

2200

600

1000

194~384

21.8

390

8

6

2200

600

1000

12-Fiber Ribbon

24~192

18.3

288

4

4

2200

600

1000

207~288

19.5

320

6

4

2200

600

1000

300~432

21.6

385

9

4

2200

600

1000

444~600

24

450

10

5

2200

600

1000

>600

Available upon customer's request

*Customized cable structure is available